The Failure of the Pressure Tube in Fuel Channel Bruce NGS-A Unit 2 in March 1986

Main Article Content

G.J. Field
M.W. Shanahan

Abstract

The events leading up to the failure of Bruce NGS-A Unit 2 pressure tube NO6 are described. Based on the subsequent examination of the tube, reactor operating history and pressure tube manufacturing information, the failure sequence is deduced. Remedial actions which have been adopted for avoiding similar occurrences are listed.

Article Details

Section
Articles