Canadian Supercritical Water Reactor Modeling Using G4STORK
Main Article Content
Abstract
The Canadian Supercritical Water Reactor design was simulated using G4STORK. The results showed the expected trends but the determined Keff of 1.253±0.001 with a Coolant Void Reactivity (CVR) of -25mk differed greatly from the results achieved using MCNP of Keff=1.2914 and a CVR of -14mk. This discrepancy is partly due to the different data libraries used and the mixing of different temperature libraries in MCNP, but is also likely due to a difference in the physics methodology. Work is ongoing to further clarify reasons for discrepancies and improve the efficiency of the simulation.
Article Details
Section
Articles