Heat Transfer Parameters for Glass-Peened Calandria Tube in Pressure Tube and Calandria Tube Contact Conditions
Main Article Content
Abstract
During a postulated event of large LOCA in CANDU reactors, the pressure tube may balloon to contact with its surrounding calandria tube to transfer heat to the moderator. To confirm the integrity of the fuel channel after the contact with a given moderator subcooling, many experiments have been performed in the last three decades by applying different pressure tube heatup rates, different pressure tube pressures and different moderator subcoolings for calandria tubes with smooth outer surface and glass-peened surface. A concept of Equivalent Moderator Subcooling (EMS) has been put forward to determine integrity of fuel channel upon pressure tube/calandria tube contact based on the existing experiment results. This concept has been presented in another work. In this work, the contact thermal conductance between pressure tube and calandria tube, critical heat flux, minimum film boiling temperature, empirical methods for nucleate boiling and film boiling heat transfer coefficient on the glass-peened calandria tube surface are discussed and estimated based on some experimental results and the EMS concept. These parameters are confirmed by simulating the existing experiments using a computer code. The estimated results may help detailed analyses on fuel channel integrity upon PT/CT contact if necessary.
Article Details
Section
Articles