A Containment Analysis for SBLOCA without ECI in the Refurbished Wolsong-1 Nuclear Power Plant
Main Article Content
Abstract
A small break leading to loss of coolant accident (SBLOCA), being one of the topic accidents in the nuclear plant diagnosis in recent years, has been analyzed and evaluated for the refurbished Wolsong-1 Nuclear Power Plant (NPP). The industry standard toolset (IST) codes developed by CANDU Owners Group and updated models including design change parameters are applied to the event analyses. GOTHIC code [1] has been used for the containment analysis of Wolsong-1. Also, SMART-IST code [2] fitted in the Iodine Chemistry (IMOD-2) model has been used to predict nuclide behavior within the containment considering various aspects. IMOD-2 was incorporated into SMART-IST as a module dealing the chemical transformations and mass transfer of iodine species in containment. IMOD-2 model is very sensitive to paint and chemicals. The parameter studies for IMOD-2 model are performed to decide the analysis value set. The developed methodology and the results of SBLOCA without ECI are presented herein. Under the most heat-up conditions, the radionuclide release from the failed fuel into the containment and subsequently to the environment is such that the radioactive doses to the public are below the acceptable limits.
Article Details
Section
Articles