A non-intrusive neutron method for gadolinium poison concentration monitoring.

Main Article Content

E.M.A. Hussein
D. OConnor
M. Mosher

Abstract

A neutron reflection method is developed for measuring the concentration of the neutron absorbing gadolinium in the tanks of the liquid poison injection shutdown system of a CANDU reactor. The feasibility of the method is demonstrated experimentally, and Monte Carlo simulations are utilized to design and model the performance of a proposed device.

Article Details

Section
Articles