Radiation Exposure Rate and Liquid Level Measurement Inside a High Level Liquid Waste (HLLW) Storage Tank

Main Article Content

Bhaskar Sur
Shuwei Yue
Arjun Thekkevarriam

Abstract

An instrument based on an inexpensive, small silicon diode has been developed and used to measure, for the first time, the gamma radiation exposure rate profile inside a 6.4 mm diameter reentrant thermo-well tube, immersed in the highly radioactive liquid solution in an HLLW storage tank. The measurement agrees with previous calculations of exposure rate, and provides confirmation for safe and effective radiation work plans and material selection for investigations and remediation of the storage tank facility. The measured radiation exposure rate profile is also used to confirm that the position of tank internal structures have not changed because of aging and corrosion, and to obtain, within a few mm, the level of liquid inside the tank.

Article Details

Section
Articles