Applying Relap5 Code to Water Hammer Analysis of the Point Lepreau HPECC Piping System
Main Article Content
Abstract
Described in this paper is the rationale for applying the RELAP5 code to water hammer analysis of the Point Lepreau HPECC piping system where incondensable gas pockets are entrapped. The preliminary water hammer consequences derived from the developed RELAP5 model are analyzed in comparison with those of real measurements and other codes.
Article Details
Section
Articles