Pickering NGS Decontaminations

Main Article Content

C.S. Lacy
B. Montford

Abstract

In early 1984, decontaminations of the Pickering N6S Units 1 and 2 heat transport systems were carried out. These decontaminations reduced radiation fields in front of the reactor face by up to a factor of 10, and resulted in radiation fields of 50 to 140 mR/h. These decontaminations were carried out using an improved version of the CAN-DECON process. This paper describes the development of the process and its successful applications at Pickering NGS.

Article Details

Section
Articles