Modification and Application of the ATHLET-SC Code to Trans-Critical Simulations

Main Article Content

Shengwei Fu
Chong Zhou
Zhihong Xu
Xiaojing Liu
Yanhua Yang
Xu Cheng

Abstract

In the simulation of trans-critical transients of Supercritical water cooled reactor (SCWR), calculation will terminate because of the sudden change in void fraction across the critical point. To solve this problem, a pseudo two-phase method is proposed with a virtual region of latent heat at pseudo-critical temperatures. A smooth variation of void fraction can be realized by using liquid-field conservation equations at temperatures lower than the pseudo-critical temperature, and vapor-field conservation equations at temperatures higher than the pseudo-critical temperature. Using this method, the system code ATHLET is modified to ATHLET-SC mod 2 on the basic of the previous modified version ATHLET-SC by Shanghai Jiao Tong University. The results of tests are verified that the calculation error with the pseudo two-phase method for supercritical fluid is acceptable, when the virtual region of latent heat is kept small. Moreover, the ATHLET-SC mod 2 code is used to simulate the pressurization and depressurization process of a single flow channel with the pressure transition as well as blowdown process. The results indicate a good applicability of the modified code.

Article Details

Section
Articles