A Multi-Physics Code System Based on ANC9, VIPRE-W and BOA for CIPS Evaluation
Main Article Content
Abstract
This paper summarizes the development of a multi-physics code system for evaluation of Crud Induced Power Shift (CIPS) phenomenon experienced in some Pressurized Water Reactors (PWR). CIPS is an unexpected change in reactor core axial power distribution, caused by boron compounds in crud deposited in the high power fuel assemblies undergoing subcooled boiling. As part of the Consortium for Advanced Simulation of Light Water Reactors (CASL) sponsored by the US Department of Energy (DOE), this paper describes the initial linkage and application of a multi- physics code system ANC9/VIPRE-W/BOA for evaluating changes in core power distributions due to boron deposited in crud. The initial linkage of the code system along with the application results will be the base for the future CASL development.
Article Details
Section
Articles