BETHSY 6.2TC Test Calculation with TRACE and RELAP5 Computer Code
Main Article Content
Abstract
The TRACE code is still under development and it will have all capabilities of RELAP5. The purpose of the present study was therefore to assess the accuracy of the TRACE calculation of BETHSY 6.2TC test, which is 15.24 cm equivalent diameter horizontal cold leg break. For calculations the TRACE V5.0 Patch 1 and RELAP5/MOD3.3 Patch 4 were used. The overall results obtained with TRACE were similar to the results obtained by RELAP5/MOD3.3. The results show that the discrepancies were reasonable.
Article Details
Section
Articles