Experimental Studies on Heat Transfer in External Cooling of the Reactor Pressure Vessel

Main Article Content

Timo Merisaari
Antti Rasanen
Antti Rasanen
Riitta Kyrki-Rajamaki
Karoliina Myllymaki
Timo Toppila

Abstract

The filling of the reactor cavity by accidental initiation of the containment spray system, while reactor is in full power, could have severe consequences. If the relatively cold water suddenly cools down the wall of fully pressurized reactor pressure vessel and a crack is assumed to be located on the outer surface of the vessel, the induced thermal stresses might damage the pressure vessel wall. The effects of the inadvertent cooling and pressurized thermal shock (PTS) were studied experimentally at Lappeenranta University of Technology and the heat transfer coefficients gained from the experimental results were compared with calculations.