Flow Boiling Critical Heat Flux Enhancement on the 2-D Slice for Boric Acid and TSP Solution
Main Article Content
Abstract
The critical heat flux (CHF) on the reactor vessel external wall was measured using the small scale two-dimensional slice test section. The radius of the curvature and the channel area of the test section were 0.15 m and 0.03 m×0.03 m, respectively. The objectives are to assess the effects of additives (TSP, boric acid) and heated material (SA508) in inclination angle 90° and to investigate flow boiling CHF enhancement resulting from various working fluids of 5000 ppm tri-sodium phosphate (TSP, Na3PO4∙12H2O) solution, 4000 ppm boric acid solution and mixture solution of TSP and boric acid. Boric acid solution didn’t show CHF enhancement and TSP and mixture solution showed CHF enhancement (20~34%).