Break Size Effect on the Transient Thermalhydraulic Behaviour During the Steam Generator Tube Rupture Accident
Main Article Content
Abstract
In order to simulate the SGTR accident of the APR1400, integral effect tests were performed by simulating a double-ended rupture of a single and five U-tubes. Following the reactor trip, the primary system pressure decreased and the secondary system pressure increased until the MSSVs was opened to reduce the secondary system pressure. Break area affected the timings of the major events observed in the tests. Less heat transfer to the secondary side caused by earlier actuation of the safety injection pumps had more influence on the secondary pressure of the affected steam generator than the break flow.
Article Details
Section
Articles