Scaling, Experiment, and Code Validation on an Integral Testing Facility

Main Article Content

Jun Yang
Sung Choi
Jaehyok Lim
Doo Lee
Somboon Rassame
Takashi Hibiki
Mamoru Ishii

Abstract

A series of integral tests simulating different types of Loss-Of-Coolant Accidents (LOCAs) for new Boiling Water Reactor (BWR) design were conducted on an integral test facility (Purdue University Multi-Dimensional Integral Test Assembly, PUMA) facility. The PUMA facility was built with a scaling methodology addressing both the conservation principles and constitutive laws. A systemic study about the safety evaluation of the advanced passively safe BWR design has been performed with the collaboration of experiments on the scaled-down test facility and RELAP5/Mod3.3 code simulation. Various types of LOCA tests were performed, such as Main Steam Line Break (MSLB), Bottom Drain Line Break (BDLB), Gravity-Driven Line Break (GDLB), and Feed Water Line Break (FWLB).

Article Details

Section
Articles