Kuosheng BWR/6 Containment Pressure and Temperature Responses After Recirculation Line Break Using GOTHIC Code
Main Article Content
Abstract
In this study, we presented the calculated results of the containment P/T (pressure and temperature) response after the recirculation line break (RCLB) accident of a GE-designed twin-unit BWR/6 plant, which can be served as the design basis for the containment system. During the simulation, a power of SPU (stretch power uprate) range was used and a model of the Mark III type containment was built using the GOTHIC (Generation of Thermal-Hydraulic Information for Containments) code. The calculated results, similar to the FSAR (Final Safety Analysis Report) results, indicate the GOTHIC code has the capability to simulate the containment P/T response to the RCLB accident.