Qualification Tests for the Failed Fuel Location System and Heat Transfer System Radioactivity Monitor Equipments

Main Article Content

G. Vieru

Abstract

This paper describes the experimental tests performed in order to prove the reliability parameters for FFLS and HTSRM equipments manufactured in INR Pitesti, for NPP CANDU Cernavoda. The tests were provided by Technical Specifications and test procedures. The laboratory tests were performed in such running and environmental conditions that correspond to the real operating ones for the equipments under testing. A special attention was paid to the accelerated tests (intensive tests), where stress level applied is above the level established by reference condition (stated by design); the acceleration of the operating conditions in the sense of a time compressing may be considered, in the case of a product where it was stated that the reliability parameters depend mainly on the number of the operating cycles, [1, 2]. A comparison, referring to the reliability parameters, between Canadian equipments and INR manufactured equipments is also given. On the other hand, there are presented reliability improvement measures taken in order to check that the equipments would operate within design specification The results of tests and the conclusions are also shown. I also mention that this paper is a partial layout of the results of the Scientific Research Contract concluded with IAEA Vienna and completed in the end of 1991, where the author have been Chief Scientific investigator.

Article Details

Section
Articles