The Demonstration Irradiation of the CANFLEX-NU Fuel Bundle in Wolsong NGS 1

Main Article Content

J.S. Jun
Jong Yeob Jung
M.S. Cho
Ho Chun Suk
Y.B. Kim
H.B. Seo

Abstract

A demonstration irradiation (DI) of 24 CANFLEX-NU fuel bundles in the high power Q07 channel and low power L21 channel of Wolsong Power Generation Station-1 had been successfully conducted jointly by KEPRI/KHNP/KAERI in the period of 2002 July to 2004 January. The tracking of the reactor operation data showed that the reactor has been stably operated during the DI. One CANFLEX bundle irradiated in the Q07 channel had a typical history of high power and high burnup, where the maximum element linear power rating was ~ 42 kW/m at the burnup of ~ 50 MWh/kgU and ~ 35 kW/m at the discharge element burnup of ~ 210 MWh/kgU. While, another CANFLEX bundles also irradiated in the Q07 channel had a typical history of power ramping, where the maximum element power ramping-up or -down rate was 28 kW/m. The unusual performance and integrity of the CANFLEX elements could not be found in the ELESTRES predictions and also the in-bay visual examinations showed that all the bundles were intact, free of defects and appeared to be in good condition as expected. Therefore, it is concluded that the demonstration irradiation shows the validation of the CANFLEX bundle performance with direct conditions of relevance under the Korean licensing requirements and the KNFC fuel fabrication capability, and provides the rationale for the decision to perform the full conversion of CANFLEX fuel in WPGS-1.

Article Details

Section
Articles