Steam Generators Secondary Side Chemical Cleaning at Point Lepreau using the Siemen's High Temperature Process

Main Article Content

Karnal Venna
Cynl MacNeil
Suat Odar
Klaus Kuhnke

Abstract

The secondary sides of all four steam generators at the Point Lepreau Nuclear Generating Station were cleaned during the 1995 annual outage run-down using the Siemens high temperature chemical cleaning process. Traditionally all secondary side chemical cleaning exercises in CANDU as well as the other nuclear power stations in North America have been conducted using a process developed in conjunction with the Electric Power Research Institute (EPRI). The Siemens high temperature process was applied for the first time in North America at the Point Lepreau Nuclear Generating Station (PLGS). The paper discusses experiences related to the pre and post award chemical cleaning activities, chemical cleaning application, post cleaning inspection results and waste handling activities.