Acoustic Tool for Leak Inspections in Steam Generator Divider Plates

Main Article Content

John Kowalewski
Peter Maak
Mike Colbert
Ken Yiu
Rick Black

Abstract

Cross flow leakage through divider plates in the primary head of steam generators, may be a contributor to RIHT rise which can have a negative effect on the operation of a plant. A method to provide quick and reliable inspection of divider plate leakage can be very useful in helping make timely and effective maintenance decisions. A novel acoustic tool for performing inspections in drained steam generators during shutdowns has been developed by OH Technologies and successfully demonstrated in a field application. The technique, referred as ALIS (acoustic leak inspection system), performs a scan of the divider plate face and presents a graphic image of the leakage paths and an estimate of the total leakage area.

Article Details

Section
Articles